Abstract
The variability between observers in the interpretation of cardiopulmonary exercise tests may impact upon clinical decision making and affect the risk stratification and peri-operative management of a patient. The purpose of this study was to quantify the inter-reader variability in the determination of the anaerobic threshold (V-slope method). A series of 21 cardiopulmonary exercise tests from patients attending a surgical pre-operative assessment clinic were read independently by nine experienced clinicians regularly involved in clinical decision making. The grand mean for the anaerobic threshold was 10.5 ml O(2).kg body mass(-1).min(-1). The technical error of measurement was 8.1% (circa 0.9 ml.kg(-1).min(-1); 90% confidence interval, 7.4-8.9%). The mean absolute difference between readers was 4.5% with a typical random error of 6.5% (6.0-7.2%). We conclude that the inter-observer variability for experienced clinicians determining the anaerobic threshold from cardiopulmonary exercise tests is acceptable.
Medical subject headings
- Anaerobic Threshold
- Preoperative Care