Role of quantitative bone scanning in the assessment of bone turnover in patients with Charcot foot.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 19933988.
- Also identified by DOI 10.2337/dc09-0950 and PMC identifier 2809280.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity. Forty-two patients with acute (n = 21) and nonacute (n = 21) CNO underwent quantitative bone scanning. Patients with acute CNO were followed for 3-12 months and bone scans were repeated after treatment. New quantitative parameters were assessed and compared with markers of bone turnover and with skin temperature difference (STD). Significant correlations between quantitative bone scan parameters and bone turnover markers were observed (all P < 0.05). These parameters decreased after treatment of CNO, and its reduction to the baseline value correlated with differences of bone turnover markers and STD (all P < 0.05). Our study suggests that bone scanning can be used not only for diagnosis of CNO but also for monitoring disease activity by quantitative bone scan parameters.
Medical subject headings
- Bone and Bones
- Gait Disorders, Neurologic
- Radiopharmaceuticals
- Technetium Tc 99m Medronate