The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 19946667.
- Also identified by DOI 10.1007/s00167-009-0990-y.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Previous studies have noted an adverse relationship between implant malalignment during total knee arthroplasty (TKA) and post-operative pain. Although some evidence exists indicating that computer-assisted surgical navigation for TKA can improve the accuracy of component alignment, its impact on clinical outcomes is currently unknown. The dual goals of the present cohort/nested case-control study were to (1) compare self-reported responses to the Western Ontario-McMaster Osteoarthritis Index (WOMAC) questionnaire between computer-assisted TKA (123 patients) using the imageless PiGalileo navigation system and conventional TKA (207 patients) [cohort analysis], and (2) to investigate a potential association between malalignment and post-operative pain in 19 painful knees and 19 asymptomatic knees obtained from the cohort analysis using matched sampling [nested case-control study]. In the cohort analysis, a relevant but non-significant (P = 0.06) difference in the occurrence of chronic pain was observed between the navigated (12%) and conventional arms (20%). Median post-operative WOMAC pain score was 100 (range, 50-100) in the conventional group and 100 (range, 65-100) in the navigated group. However, the Mann-Whitney test revealed a significant difference in favor of the navigated group (P = 0.01). In the nested case-control analysis, radiological outcomes and computer tomography (CT) measurements of femoral rotation were compared between the groups. The CT rotation measurements yielded evidence of a relationship between post-operative pain and incorrect rotational alignment of the femoral component of more than 3 degrees (OR: 7; 95% CI: 1.2-42; P = .033). In conclusion, there was no clinical benefit to computer-assisted navigation; however, a statistically significant relationship was observed between incorrect rotational alignment of the femoral component and symptoms of post-operative pain following TKA.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Surgery, Computer-Assisted
Anatomy
- knee