Principles of biomimetic vascular network design applied to a tissue-engineered liver scaffold.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 20001254.
- Also identified by DOI 10.1089/ten.TEA.2009.0118 and PMC identifier 2952124.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Branched vascular networks are a central component of scaffold architecture for solid organ tissue engineering. In this work, seven biomimetic principles were established as the major guiding technical design considerations of a branched vascular network for a tissue-engineered scaffold. These biomimetic design principles were applied to a branched radial architecture to develop a liver-specific vascular network. Iterative design changes and computational fluid dynamic analysis were used to optimize the network before mold manufacturing. The vascular network mold was created using a new mold technique that achieves a 1:1 aspect ratio for all channels. In vitro blood flow testing confirmed the physiologic hemodynamics of the network as predicted by computational fluid dynamic analysis. These results indicate that this biomimetic liver vascular network design will provide a foundation for developing complex vascular networks for solid organ tissue engineering that achieve physiologic blood flow.
Medical subject headings
- Biomimetic Materials
- Blood Vessels
- Liver
- Tissue Engineering
- Tissue Scaffolds