Immunologic adverse reaction associated with low-carbide metal-on-metal bearings in total hip arthroplasty.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 20020335.
- Also identified by DOI 10.1007/s11999-009-1187-x and PMC identifier 2895854.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An increased incidence of periprosthetic osteolysis, resulting in loss of biologic fixation, has been reported in contemporary THAs with low-carbide metal-on-metal compared with metal-on-polyethylene couple bearings. Although a hypersensitivity reaction attributable to Co and Cr debris is reportedly a potential cause for failure of THAs with high-carbide bearings, there are no evidence-based data for this reaction in low-carbide metal-on-metal bearings, although such hypersensitivity might be related to osteolysis. We investigated whether there were differences in immunologic hypersensitivity reactions in retrievals from revised THAs with ceramic-on-polyethylene versus metal-on-metal bearing couples. We compared newly formed capsule and periprosthetic interface membranes from revision surgery for aseptic failure from 20 patients with low-carbide bearings and 13 patients with ceramic-on-polyethylene bearings. For control tissue, we obtained samples from the hip capsule during the primary THA implantation in 13 patients with low-carbide bearings and seven with ceramic-on-polyethylene bearings. We examined the tissues with conventional histologic and immunohistochemical methods. Compared with tissue from the control subjects and patients with ceramic-on-polyethylene bearings, the tissues from patients with low-carbide metal-on-metal bearings were associated with (1) extensive necrosis and fibrin exudation in the newly formed hip capsule and (2) diffuse and perivascular lymphocytic infiltration of a higher degree than in the hips with ceramic-on-polyethylene bearings in conventional histologic examination, and (3) more T than B cells. The conventional histologic and immunohistochemical findings in tissues retrieved from failed THAs with low-carbide metal-on-metal bearings are consistent with a link between hypersensitivity and osteolysis with low-carbide bearing couples.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Chromium Alloys
- Hip Prosthesis
- Hypersensitivity, Delayed
- Metals
Anatomy
- hip