Results of isolated femoral component revision with well-fixed acetabular implant retention.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 20189344.
- Also identified by DOI 10.1016/j.arth.2009.12.015.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The present study was undertaken to evaluate the clinical and radiological results of isolated femoral revisions conducted while retaining well-fixed cementless acetabular sockets. Thirty-nine patients that underwent isolated femoral stem revisions were reviewed. Mean age at time of surgery was 60.5 years, and mean follow-up duration was 4.2 years. Decisions to retain acetabular sockets were based on clinical and radiographic findings and intraoperative stabilities. During revisions, polyethylene liners were exchanged for metal-inlay polyethylene liners to have a metal-on-metal bearing surface in 23 cases. Mean Harris hip score improved from 58 points preoperatively to 85 points at final follow-up (P < .001). With the exception of one patient, no increases in acetabular radiolucent line numbers or thicknesses were observed during follow-up visits. Isolated femoral stem revisions with acetabular socket retention were found to provide excellent clinical and radiographic results.
Medical subject headings
- Acetabulum
- Arthroplasty, Replacement, Hip
- Femur
- Hip Prosthesis
Anatomy
- femur
- hip