Determination of axial vertebral rotation in MR images: comparison of four manual and a computerized method.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 20204425.
- Also identified by DOI 10.1007/s00586-010-1340-y and PMC identifier 2899965.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Axial vertebral rotation (AVR) of 14 normal and 14 scoliotic vertebrae from magnetic resonance (MR) images was determined by three observers using four manual methods and a computerized method, which were based on the evaluation of vertebral symmetry in two dimensions (2D) and in three dimensions (3D). The method of Aaro and Dahlborn proved to be the manual method with the highest intra-observer (1.7 degrees SD) and inter-observer (1.2 degrees SD) reliabilities, and was also most in agreement with the computerized method (1.3 degrees SD, 1.0 degrees MAD). The computerized method yielded higher intra-observer (1.3 degrees SD) and inter-observer (1.4 degrees SD) reliabilities than the manual methods, indicating it to be an efficient alternative for repeatable and reliable AVR measurements.
Medical subject headings
- Lumbar Vertebrae
- Rotation
- Scoliosis
- Thoracic Vertebrae
Anatomy
- lumbar spine
- thoracic spine