Endovascular management of multiple arteriovenous fistulae following failed laser-assisted pacemaker lead extraction.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 20304582.
- Also identified by DOI 10.1016/j.jvs.2009.12.069.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A woman presented for evaluation of new-onset left arm edema after failed laser-assisted pacemaker lead extraction. Initial workup demonstrated a left subclavian artery to vein arteriovenous fistula (AVF). She underwent repair of the AVF with placement of a covered stent in the subclavian artery, however, her symptoms did not completely resolve. Investigation revealed a left common carotid artery to left innominate vein AVF, which was repaired by deploying a covered stent retrograde into the left common carotid artery. Her symptoms subsequently resolved. Multiple iatrogenic AVF can be repaired endovascularly, however, a high degree of suspicion for multiple injuries should be maintained.
Medical subject headings
- Arteriovenous Fistula
- Blood Vessel Prosthesis Implantation
- Brachiocephalic Veins
- Carotid Artery, Common
- Device Removal
- Lasers, Excimer
- Pacemaker, Artificial
- Subclavian Artery
- Subclavian Vein