Fibreoptic bronchoscopy without general anaesthetic.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 2031604.
- Also identified by PMC identifier 1793008.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We have used flexible fibreoptic bronchoscopy using sedation and local anaesthesia in 50 children aged 2-19 years (median 10) using an Olympus BFP20 instrument. Indications were opportunistic pneumonias (n = 11), persistent atelectasis (n = 11), recurrent pneumonia (n = 7), miscellaneous lower airway disease (n = 7), recurrent wheezing (n = 3), haemoptysis (3), to diagnose infection or rejection of heart-lung transplants (n = 3), stridor (n = 2), suspected airway compression (n = 1), evaluation of tracheostomy (n = 1), and suspected foreign body (n = 1). In 43 cases (86%) the diagnosis was related to the primary indication. In five (10%) unrelated abnormalities were found, and five (10%) were normal. In 13 (26%) treatment was altered as a result of flexible fibreoptic bronchoscopy. Complications were transient respiratory arrest (n = 2), hypoxia (n = 2), pneumonia (n = 2), and laryngospasm (n = 1). All complications were followed by complete recovery. Our results suggest that flexible fibreoptic bronchoscopy is safe. Advantages over rigid bronchoscopy include greater visual range, fewer complications, and the avoidance of a general anaesthetic. Though invasive it can yield important diagnostic and therapeutic information.
Medical subject headings
- Anesthesia, Local
- Bronchoscopy
- Procedural Sedation