The use of capnography and the availability of airway equipment on Intensive Care Units in the UK and the Republic of Ireland.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 20337619.
- Also identified by DOI 10.1111/j.1365-2044.2010.06308.x.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
At least 20% of reported major adverse airway events occur on the intensive care unit. This study surveyed 315 (96%) of all general, satellite, hepatobiliary, cardiac and neuro-intensive care units in the UK and the Republic of Ireland, finding that only 100 (32%) units always use capnography for tracheal intubation while only 80 (25%) always use capnography for continuous monitoring of patients requiring controlled ventilation. Three hundred and ten (98%) units utilise a checklist of airway equipment, 311 (99%) check its functionality on a daily basis and 296 (94%) units have access to a bronchoscope. Whilst 297 (94%) ICUs have an airway trolley, sufficient equipment for unanticipated difficult intubation was only seen on 33 (10%) of units. Guidelines addressing minimum standards for monitoring and airway safety on ICU are not being met and remain below the standard expected.
Medical subject headings
- Capnography
- Intensive Care Units
- Intubation, Intratracheal