Video-assisted thoracoscopic indocyanine green fluorescence imaging system shows sentinel lymph nodes in non-small-cell lung cancer.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 20392454.
- Also identified by DOI 10.1016/j.jtcvs.2010.01.028.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The primary objective was to assess the feasibility and accuracy of intraoperative sentinel lymph node mapping by using a video-assisted thoracoscopic indocyanine green fluorescence imaging system in patients with clinical stage I non-small-cell lung cancer. Thirty-one patients who underwent operation between January 2009 and September 2009 were investigated for sentinel node biopsy. Indocyanine green fluorescence imaging was applied by an infrared light charge-coupled device, and sentinel nodes were identified intraoperatively and dissected. Histologic examination by hematoxylin-eosin staining was used to evaluate metastases. Sentinel lymph nodes were identified by segmentectomy in 11 of 14 patients (78.5%) and by lobectomy in 14 of 17 patients (82.4%). The total identification rate was 80.7% (25/31 patients), the false-negative rate was 0% (0/24 patients), and the overall accuracy rate was 80.7% (25/31 patients). Video-assisted thoracoscopic indocyanine green fluorescence image-guided surgery is feasible for sentinel node biopsy and may be a powerful tool to eliminate unnecessary lymph node dissection in patients with lung cancer.
Medical subject headings
- Carcinoma, Non-Small-Cell Lung
- Fluorescent Dyes
- Indocyanine Green
- Lung Neoplasms
- Sentinel Lymph Node Biopsy
- Thoracic Surgery, Video-Assisted