Failure of the interosseous membrane to heal with immobilization, pinning of the distal radioulnar joint, and bipolar radial head replacement in a case of Essex-Lopresti injury: case report.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 20452146.
- Also identified by DOI 10.1016/j.jhsa.2010.03.004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors report a case of a patient with complex radial head and ulnar shaft fractures with an associated tear of the interosseous membrane, which failed to heal despite open reduction internal fixation of the ulna, a bipolar radial head replacement, and cross pinning of the distal radioulnar joint. This case demonstrates that failure of the interosseous membrane can occur even in a properly replaced bipolar radial head with adequate immobilization of the forearm and pinning of the distal radioulnar joint.
Medical subject headings
- Fracture Fixation, Internal
- Fractures, Comminuted
- Joint Instability
- Radius Fractures
- Ulna Fractures
- Elbow Injuries
Anatomy
- elbow
- radius
- ulna
- radius/ulna
- wrist