Iatrogenic air leak successfully treated by bronchoscopic placement of unidirectional endobronchial valves.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 20494069.
- Also identified by DOI 10.1016/j.athoracsur.2009.10.015.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This report describes a patient with persistent air leak after inadvertent placement of a chest drain in a bulla. Chest drain and suction failed to stop the air leak, whereas the surgical repair was judged to be excessively aggressive. In closure, two large endobronchial valves were sequentially positioned in the superior and inferior division of the left upper lobe to completely close it. The result was the collapse of bulla with closure of fistula and complete lung expansion.
Medical subject headings
- Bronchoscopy
- Lung Diseases