Thermal necrosis after simultaneous tibial osteotomy and total knee arthroplasty using press-fit extension-stem.

Ishida, Kazunari; Tsumura, Nobuhiro; Takayama, Koji; Fukase, Naomasa; Kitagawa, Atsushi; Chin, Takaaki; Iguchi, Tetsuhiro; Matsumoto, Tomoyuki et al. · Knee Surg Sports Traumatol Arthrosc · 2011

case_report · Level V

Where this comes from

Abstract

One-staged tibial corrective osteotomy and total knee arthroplasty is a challenging but effective treatment for arthritic knees with extra-articular deformity. Although osteocutaneous thermal necrosis is accepted as a complication of intramedullary reamed nailing following long bone fractures, only 15 cases have been reported in the English literature at present. This report illustrates a rare case of thermal necrosis in a patient undergoing tibial corrective osteotomy coincident with long-stemmed total knee arthroplasty. Excessive reaming with a machine reamer is hypothesized as the cause of this serious complication. In this report, we highlight this rare but serious complication after long-stemmed total knee arthroplasty.