Leukocyte SPECT/CT for detecting infection of left-ventricular-assist devices: preliminary results.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 20554736.
- Also identified by DOI 10.2967/jnumed.109.070664.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report our experience with using integrated molecular and anatomic hybrid imaging to assess infection in patients who have a left-ventricular-assist device (LVAD). Thirteen (99m)Tc-exametazime-leukocyte planar and SPECT/CT scans were obtained for 8 consecutive patients who had an implanted LVAD. SPECT/CT was used to assess suspected device-related infections (n = 8) and to evaluate the efficiency of current antibiotic therapy (n = 5). Device-related infection was seen on 8 of the 13 scans. SPECT/CT was positive for infection in all 8 patients, whereas planar scans were positive in 6 of 8. SPECT/CT provided relevant information on the extent of infection and its exact location in all patients. Additional distant infectious foci were demonstrated in 3 of 13 patients. SPECT/CT led to an accurate diagnosis of LVAD-related infection, revealing both anatomic location and extent. This noninvasive approach could lead to improved therapeutic strategies.
Medical subject headings
- Heart-Assist Devices
- Leukocytes
- Prosthesis-Related Infections