Proficiency survey-based evaluation of clinical total and allergen-specific IgE assay performance.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 20586624.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The diagnostic algorithm for human allergic disease involves confirmation of sensitization by detection of allergen-specific immunoglobulin E (IgE) antibody in individuals suspected of having allergic disease because of a history of allergic symptoms after known allergen exposure. Previous studies showed wide disparity among clinically reported allergen-specific IgE levels from different serologic assays. To validate the relative analytic performance (sensitivity, interassay reproducibility, linearity/parallelism, intermethod agreement) of clinically used total and allergen-specific IgE assays by using College of American Pathologists' Diagnostic Allergy "SE" Proficiency Survey data. Data from 2 SE survey cycles were used to assess relative analytic performance of the ImmunoCAP (Phadia), Immulite (Siemens Healthcare-Diagnostics), and HYTEC 288 (HYCOR-Agilent Technologies) total and allergen-specific IgE assays. In each cycle, 2 recalcified plasma pools from atopic donors were diluted twice with IgE-negative serum and evaluated in approximately 200 federally certified clinical laboratories for total IgE and IgE antibody to 5 allergen specificities. Statistical analysis evaluated analytic sensitivity, linearity, reproducibility, and intermethod agreement. Interlaboratory intramethod, intermethod, and interdilution agreement of all 6 clinically used total serum IgE assays were excellent, with coefficients of variation (CVs) below 15%. Interlaboratory intramethod, and interdilution agreement of 3 clinically used allergen-specific IgE assays were also excellent with CVs below 15%. However, intermethod CVs identified between-assay disagreement greater than 20% in 80% of allergen-specific IgE measurements. Allergen reagents and patients' immune response heterogeneity are suggested probable causes. Clinical total and allergen-specific IgE assays display excellent analytic sensitivity, precision, reproducibility, and linearity. Marked variability in quantitative estimates of allergen-specific IgE from clinically used automated immunoassays is a concern that may be ameliorated with component allergen use.
Medical subject headings
- Allergens
- Epitopes
- Hypersensitivity
- Immunoglobulin E
- Pathology