RAST-detection of specific IgE in diphenylmethane diisocyanate exposed workers: considerations in performance of the test.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 2058811.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Some parameters which might affect RAST results, i.e. incubation length, degree of ligand substitution, and total IgE levels, were examined in a RAST system employing diphenylmethane diisocyanate--human serum albumin (MDI-HSA) conjugates as antigens, both in exposed symptomatic and in non-exposed subjects. The reaction equilibrium was reached after 9 and 18 h. respectively, in the first and the second step of the test. A marked correlation with the degree of ligand substitution was observed, the highest sensitivity being achieved with the lowest (2.9) MDI/HSA molar ratio examined. Higher (up to 50) degrees of substitution resulted in progressively lower levels of radioactivity bound and in a loss of specificity, as confirmed by RAST inhibition experiments. At high levels of ligand substitution, high titers of total serum IgE affected RAST results.
Medical subject headings
- Asthma
- Cyanates
- Immunoglobulin E
- Isocyanates
- Occupational Diseases
- Radioallergosorbent Test