Cytostatic extravasation. A serious complication of long-term venous access.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 2065273.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Totally implantable ports have gained popularity as venous access in the treatment of cancer. A case is reported with an uncommon but very serious complication, i.e., cytostatic extravasation secondary to a broken implanted catheter. Guidelines for implantation and remedies are recommended.
Medical subject headings
- Catheters, Indwelling
- Extravasation of Diagnostic and Therapeutic Materials
- Infusion Pumps, Implantable
- Leukemia, Myeloid