Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in vitro and in vivo study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 20656839.
- Also identified by DOI 10.1148/radiol.10092086.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the effect of beam hardening on arterial enhancement in thoracoabdominal computed tomographic (CT) angiography in various body sizes in a phantom and in a clinical study. An abdominal aortic phantom was placed in three cylindrical water containers simulating a small, an intermediate, and a large patient (diameters of 22, 30, and 40 cm, respectively). CT scanning was performed at 80, 100, and 120 kVp, and aortic attenuation was assessed. In a HIPAA-compliant institutional review board-approved study with waiver of informed consent, thoracoabdominal aortic attenuation was assessed in 100 consecutive patients (75 men, 25 women; mean body weight (BW), 79 kg) undergoing thoracoabdominal 64-section CT angiography at 80 kVp. Overall aortic attenuation in patients grouped according to BW (small patients [n = 26], <70 kg; intermediate patients [n = 41], 70-85 kg; large patients [n = 33], >85 kg) was compared. Overall aortic attenuation was correlated with BW, height, body mass index (BMI), body surface area (BSA), and lateral diameter by using linear regression. Comparison of the intermediate- and large-phantom groups relative to the small-phantom group indicated that mean aortic attenuation decreased by 9.7% and 13.4% at 80 kVp, 9.8% and 15.1% at 100 kVp, and 13.8% and 23.8% at 120 kVp, respectively (P < .001). In the clinical study, the overall aortic attenuation decreased by 11.3% and 20.0% in the intermediate- and large-patient groups relative to the small-patient group, respectively (P < .05). Overall aortic attenuation correlated well with BSA (R = -0.454), height (R = -0.421), and BW (R = -0.414), followed by lateral diameter (R = -0.291) and BMI (R = -0.211). Beam hardening may substantially contribute to reduced arterial enhancement in larger patients undergoing thoracoabdominal CT angiography. The beam-hardening effect on arterial enhancement is more pronounced at higher tube voltages.
Medical subject headings
- Angiography
- Aortic Aneurysm
- Aortography
- Body Size
- Radiographic Image Enhancement
- Tomography, X-Ray Computed