Nonunion of capital femoral physeal fracture with a large metaphyseal fragment.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 20657240.
- Also identified by DOI 10.1097/BOT.0b013e3181c83a3b.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure and avascular necrosis of the femoral head, so internal fixation using cannulated screws and percutaneously drilling with a Kirschner wire to the metaphyseal fragment was used and was effective in bone union without these complications.
Medical subject headings
- Bone Screws
- Bone Wires
- Femoral Neck Fractures
- Fracture Fixation, Internal
- Fractures, Ununited
Anatomy
- femur