Surgical difficulties encountered with use of modular endoprosthesis for limb preserving salvage of failed allograft reconstruction after malignant tumor resection.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 20692805.
- Also identified by DOI 10.1016/j.arth.2010.06.011.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We reviewed outcomes and discussed surgical difficulties encountered in 10 patients who had modular endoprosthesis for limb preserving salvage of failed allograft reconstruction after malignant tumor resection. Mean allograft survival time before failure was 127.4 months (range, 14-264 months). Mean length of follow-up since endoprosthesis revision surgery was 62.8 months (range, 16-132 months). There was one endoprosthesis failure, resulting in a mean endoprosthesis survival time of 56.9 months (range, 16-132). Complications included arterial laceration, nerve injury, periprosthetic crack fracture, aseptic loosening, and infection. Modular endoprosthesis remain a viable option that should be considered in any limb preserving salvage of failed allograft reconstructions. However, altered anatomy, poor/short remnant host bone, periprosthetic fractures, inadequate soft tissue coverage and infection remain important difficulties encountered.
Medical subject headings
- Artificial Limbs
- Bone Neoplasms
- Femur
- Humerus
- Limb Salvage
- Orthopedic Procedures
- Tibia
Anatomy
- femur
- humerus
- tibia