Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 20799945.
- Also identified by DOI 10.1186/1749-799X-5-62 and PMC identifier 2939628.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM) system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten weeks post surgery. The patient was subsequently treated with Lag Screw removal and revision surgery with a shorter Lag Screw and an accessory cannulated screw acting as a de-rotational device. The patient did well with the revision surgery and was able to return to full activities.
Anatomy
- hip