Anatomic outcome of percutaneous release among patients with trigger finger.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 20800975.
- Also identified by DOI 10.1016/j.jhsa.2010.06.006.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To investigate the adequacy and safety of percutaneous trigger finger release on symptomatic patients. Two orthopedic non-hand surgeons performed percutaneous A1 pulley release on the thumb, index, middle, and ring fingers with the use of a 19-gauge needle in 25 fingers of 24 patients. Open inspection was then performed to determine the extent of release and any injury to the surrounding anatomic structures. Triggering was eliminated in all fingers. Of the 25 A1 pulleys, 19 were partially released; only 6 were completely released. Noted injury included only superficial abrasions in 15 tendons. None of the patients had injury to the digital artery or nerve. In the percutaneous release of trigger fingers, complete anatomic release of the A1 pulley is not always adequately achieved, even though clinically patients experience relief of triggering. It is a safe procedure for the thumb, index, middle, and ring fingers as long as the recommended technique is observed.
Medical subject headings
- Trigger Finger Disorder