A transversely isotropic constitutive model of excised guinea pig spinal cord white matter.

Galle, Beth; Ouyang, Hui; Shi, Riyi; Nauman, Eric · J Biomech · 2010

biomechanical · Level V

Where this comes from

Abstract

Narrowing of the spinal canal generates an amalgamation of stresses within the spinal cord parenchyma. The tissue's stress state cannot be quantified experimentally; it must be described using computational methods, such as finite element analysis. The objective of this research was to propose a compressible, transversely isotropic constitutive model, an augmentation of the isotropic Mooney-Rivlin hyperelastic strain energy function, to describe the guinea pig spinal cord white matter. Model parameters were derived from a combination of inverse finite element analysis on transverse compression experiments and least squared error analysis applied to quasi-static longitudinal tensile tests. A comparison of the residual errors between the predicted response and the experimental measurements indicated that the transversely isotropic constitutive law that incorporates an offset stretch reduced the error by a factor of four when compared to other commonly used models.

Medical subject headings