Mobile and fixed-bearing (all-polyethylene tibial component) total knee arthroplasty designs: surgical technique.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 20844179.
- Also identified by DOI 10.2106/JBJS.J.00157.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Proponents of mobile-bearing total knee arthroplasty believe that it has potential advantages over a fixed-bearing design in terms of diminished wear and improved motion and/or function, but these advantages have not been demonstrated in a randomized clinical comparison to our knowledge. We conducted a patient-blinded, prospective, randomized clinical trial to compare mobile-bearing and fixed-bearing cruciate-substituting total knee arthroplasties of the same design. Patients between the ages of sixty and eighty-five years were prospectively randomized to receive a cruciate-substituting rotating-platform design or a fixed-bearing design with an all-polyethylene tibial component. There were no significant differences in the demographic characteristics (mean age, 72.2 years; mean American Society of Anesthesiologists score, 2.7; mean body mass index, 31.8 kg/m2) or preoperative clinical or radiographic measures between the groups. Routine clinical and radiographic follow-up measures included the Knee Society score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Short Form-36 (SF-36) outcome measures. The results of 312 arthroplasties (136 with an all-polyethylene tibial component and 176 rotating-platform designs) in 273 patients were analyzed at a minimum of two years (mean, forty-two months) postoperatively. Although there was significant improvement in both groups, there was no significant difference between the groups with regard to the mean postoperative range of motion (110.9° and 109.1°, respectively; p = 0.21), the mean KSS clinical score (90.4 and 88.2 points; p = 0.168), or the mean KSS pain score (44.9 and 43.1 points; p = 0.108) at this follow-up point. There were ten revisions: seven because of infection, one because of patellar fracture, one because of instability, and one because of aseptic loosening. The two designs functioned equivalently at the time of early follow-up in this low-to-moderate-demand patient group. The rotating-platform design had no significant clinical advantage over the design with the all-polyethylene tibial component.
Medical subject headings
- Aged
- Aged, 80 and over
- Arthroplasty, Replacement, Knee
- Arthroplasty, Replacement, Knee/methods
- Female
- Follow-Up Studies
- Humans
- Knee Prosthesis
- Male
- Osteoarthritis, Knee
- Osteoarthritis, Knee/diagnosis
- Osteoarthritis, Knee/surgery
- Pain Measurement
- Polyethylenes
- Polyethylenes/pharmacology
- Prospective Studies
- Prosthesis Design
- Prosthesis Implantation
- Prosthesis Implantation/methods
- Range of Motion, Articular
- Range of Motion, Articular/physiology
- Recovery of Function
- Risk Assessment
- Severity of Illness Index
- Single-Blind Method
- Treatment Outcome
Anatomy
- knee
- tibia