Clinical experience using Cortoss for treating vertebral compression fractures with vertebroplasty and kyphoplasty: twenty four-month follow-up.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 20844420.
- Also identified by DOI 10.1097/BRS.0b013e3181dcda75.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Forty patients were enrolled in 2 FDA-approved pilot Investigational Device Exemption (IDE) studies using Cortoss for the treatment of vertebral compression fractures (VCF). Twenty patients were treated at 3 centers, using vertebroplasty (VP) and 20 patients were treated at 5 centers, using kyphoplasty (KP). To assess the feasibility and clinical outcomes using Cortoss to treat osteoporotic VCF. Cortoss is an injectable bioactive, self-setting, radiopaque composite shown to stabilize and provide immediate weight bearing support to fractured vertebrae. Cortoss is approved for use in Europe for both screw and vertebral augmentation. METHODS.: Patient assessments were conducted before surgery and after surgery through 24 months using Visual Analog Scale (VAS), Oswestry Disability Index (ODI), and quality-of-life assessment (SF-12) questionnaires. Extravasations were evaluated using radiographs and CT scans. Immediate pain improvement was seen in VP patients with VAS scores decreasing from 75.7 before surgery to 35.9 at 72 hours. Continued improvement from baseline was seen out to 2 years (average VAS of 48.9). Disability improved with average ODI scores decreasing from 52.2% preoperative to 38.3% at 2 years for VP patients. Immediate pain improvement was also seen in KP patients with VAS scores decreasing from 78.1 before surgery to 42.7 at 72 hours. Continued improvement from baseline was seen out to 2 years (average VAS of 25.4). ODI scores improved from 60.5% preoperative to 34.5% at 2 years for KP patients. Average material volumes injected were 1.85 mL for VP and 4.13 mL for KP. Extravasations from both techniques were minor, anatomically close to the treated vertebrae and asymptomatic. No cardiac irregularities or pulmonary emboli were observed. These studies indicate Cortoss is safe and effective in treating osteoporotic VCF using vertebroplasty or kyphoplasty. Pain relief and restoration of function with Cortoss is comparable to results found in the literature for polymethylmethacrylate.
Medical subject headings
- Bisphenol A-Glycidyl Methacrylate
- Fractures, Compression
- Kyphoplasty
- Spinal Fractures
- Vertebroplasty