Directed air flow to reduce airborne particulate and bacterial contamination in the surgical field during total hip arthroplasty.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 20851565.
- Also identified by DOI 10.1016/j.arth.2010.07.001.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study evaluated the use of a system that delivers a small field of local, directed air from a high-efficiency particulate air (HEPA) filter to reduce airborne particulate and airborne bacteria in the surgical field during total hip arthroplasty. Thirty-six patients were randomized into 3 groups: with directed air flow, with the directed air flow system present but turned off, and control. Airborne particulate and bacteria were collected from within 5 cm of the surgical wound. All particulate and bacterial counts at the surgical site were significantly lower in the directed air flow group (P < .001). The directed air flow system was effective in reducing airborne particulate and colony-forming units in the surgical field during total hip arthroplasty.
Medical subject headings
- Air Pollution, Indoor
- Arthroplasty, Replacement, Hip
- Bacterial Infections
- Operating Rooms
- Particulate Matter
- Surgical Wound Infection
- Ventilation