A trigger tool fails to identify serious errors and adverse events in pediatric otolaryngology.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 20869555.
- Also identified by DOI 10.1016/j.otohns.2010.06.820.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To identify and quantify errors and adverse events on an inpatient academic tertiary-care pediatric otolaryngology service, a trigger tool was developed and validated as part of a quality improvement initiative. Retrospective record review. Children's Hospital Boston quality improvement initiative. Fifty inpatient admissions were reviewed. The gold standard for errors and adverse events identification was a detailed chart review by two board-certified otolaryngologists blinded to trigger tool findings. Trigger tool interrater reliability ranged from poor to high for admission triggers (kappa = 0.35, 95% confidence interval [95% CI] -0.07 to 0.76), discharge triggers (kappa = 0.63, 95% CI 0.27-0.99), medical records triggers (kappa = 0.61, 95% CI 0.11-1.00), and medication triggers (kappa = 0.90, 95% CI 0.71-1.00). Errors and adverse events were found in all admissions: three percent were potentially harmful, and 93 percent were documentation-related. The trigger tool was successful in identifying clerical and administrative errors and adverse events but failed to identify complex errors and adverse events. A hybrid approach for chart review may be cost-effective in pediatric otolaryngology.
Medical subject headings
- Medical Errors
- Otorhinolaryngologic Surgical Procedures