Improving epinephrine responses in hypoglycemia unawareness with real-time continuous glucose monitoring in adolescents with type 1 diabetes.

Ly, Trang T; Hewitt, Jacqueline; Davey, Raymond J; Lim, Ee Mun; Davis, Elizabeth A; Jones, Timothy W · Diabetes Care · 2011

rct · Level II

Where this comes from

Abstract

To determine whether real-time continuous glucose monitoring (CGM) with preset alarms at specific glucose levels would prove a useful tool to achieve avoidance of hypoglycemia and improve the counterregulatory response to hypoglycemia in adolescents with type 1 diabetes with hypoglycemia unawareness. Adolescents with type 1 diabetes with hypoglycemia unawareness underwent hyperinsulinemic hypoglycemic clamp studies at baseline to determine their counterregulatory hormone responses to hypoglycemia. Subjects were then randomized to either standard therapy or real-time CGM for 4 weeks. The clamp study was then repeated. The epinephrine response during hypoglycemia after the intervention was greater in the CGM group than in the standard therapy group. A greater epinephrine response during hypoglycemia suggests that real-time CGM is a useful clinical tool to improve hypoglycemia unawareness in adolescents with type 1 diabetes.

Medical subject headings