Peripheral arterial occlusive disease: evaluation of a high spatial and temporal resolution 3-T MR protocol with a low total dose of gadolinium versus conventional angiography.

Attenberger, Ulrike I; Haneder, Stefan; Morelli, John N; Diehl, Steffen J; Schoenberg, Stefan O; Michaely, Henrik J · Radiology · 2010

retrospective_cohort · Level III

Where this comes from

Abstract

To evaluate a peripheral magnetic resonance (MR) angiographic protocol combining continuous table movement (CTM) MR angiography of the entire runoff vasculature with time-resolved (TWIST) 3-T MR angiography of the calves with a total gadolinium dose of 0.1 mmol per kilogram of body weight. In this retrospective institutional review board-approved study, 31 consecutive patients (22 men, nine women; mean age, 65 years ± 14 [standard deviation]) with peripheral arterial occlusive disease who had undergone a low-dose MR angiographic protocol that consisted of CTM MR angiography (repetition time msec/echo time msec, 2.4/1.0; 21° flip angle; voxel size, 1.2 mm(3); gadolinium dose, 0.07 mmol per kilogram of body weight) and TWIST MR angiography (2.8/1.1; 20° flip angle; voxel size, 1.1 mm(3); temporal resolution, 4.8-5.5 sec, gadolinium dose, 0.03 mmol/kg), as well as digital subtraction angiography (DSA), were included. Two radiologists rated image quality and stenosis degree on four-point scales. The accuracy of stenosis gradation and, specifically, the detection of high-grade stenoses (stenosis of 70%-99%) with CTM MR angiography alone and with the combined protocol were compared with accuracy of stenosis gradation and detection of high-grade stenoses with DSA. Means and standard deviations were calculated for all data. Interobserver agreement was determined with κ statistics. Positive and negative predictive values, sensitivity, specificity, and overall diagnostic accuracy were calculated for CTM MR angiography alone and for the combined protocol. For CTM MR angiography, image quality was good or excellent in 95.9% of vessel segments; for TWIST MR angiography, image quality was good or excellent in 94.3% and 97.8% of vessel segments for readers 1 and 2, respectively. The combined protocol resulted in high overall diagnostic accuracy of more than 80% for detection of stenosis and diagnostic accuracy of 93.5% for detection of high-grade vessel stenosis. Inclusion of TWIST MR angiography increased diagnostic value over that achieved with CTM MR angiography alone. A combined MR angiographic approach in which a low total gadolinium dose (0.1 mmol/kg) is used yields excellent image quality and is accurate in the diagnosis of peripheral arterial stenosis.

Medical subject headings