Early range of motion of the scorpio non-restrictive geometry cruciate-retaining total knee system.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 21036012.
- Also identified by DOI 10.1016/j.arth.2010.07.014.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Flexion following total knee arthroplasty in the US population generally falls between 100° and 120°. Because of these relatively low flexion arcs, total knee arthroplasty prosthetic designs emerged allowing "high flexion" (≥125°). We hypothesized that a high-flexion implant design, Scorpio Non-Restrictive Geometry cruciate-retaining knee prosthesis, would allow clinical early maximum flexion of at least 125°. A prospective observational cohort study enrolled 87 unselected patients (94 knees) evaluated preoperation and 3 months and 1 year postoperation for clinical flexion, arc of motion, and Knee Society scores. At 1 year, 67% of knees had improved flexion and 23% achieved flexion of at least 125°. Clinically, flexion improved by 6.9° and total arc of motion improved by 10.6° from preoperation to 1-year postoperation. Although this high-flexion design allows increased flexion, many patients fail to achieve flexion of at least 125°.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee Joint
- Knee Prosthesis
- Posterior Cruciate Ligament
- Prosthesis Design
- Range of Motion, Articular
Anatomy
- knee