Speeded near infrared spectroscopy (NIRS) response detection.
Where this comes from
- Record sourced from PubMed, PMID 21085607.
- Also identified by DOI 10.1371/journal.pone.0015474 and PMC identifier PMC2818571.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The hemodynamic response measured by Near Infrared Spectroscopy (NIRS) is temporally delayed from the onset of the underlying neural activity. As a consequence, NIRS based brain-computer-interfaces (BCIs) and neurofeedback learning systems, may have a latency of several seconds in responding to a change in participants' behavioral or mental states, severely limiting the practical use of such systems. To explore the possibility of reducing this delay, we used a multivariate pattern classification technique (linear support vector machine, SVM) to decode the true behavioral state from the measured neural signal and systematically evaluated the performance of different feature spaces (signal history, history gradient, oxygenated or deoxygenated hemoglobin signal and spatial pattern). We found that the latency to decode a change in behavioral state can be reduced by 50% (from 4.8 s to 2.4 s), which will enhance the feasibility of NIRS for real-time applications.