Evaluation of heparin assay for coagulation management in newborns undergoing ECMO.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 21088159.
- Also identified by DOI 10.1309/AJCPGVD62LKKVDLH.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective was to identify the usefulness of heparin level by anti-factor Xa (anti-Xa) assay vs activated partial thromboplastin time (PTT) or activated clotting time (ACT) in neonates undergoing extracorporeal membrane oxygenation (ECMO). A retrospective record review of 21 patients in the neonatal intensive care unit (mean ECMO initiation age, 2 days; range, 0-4 days; male/female ratio, 1:1) undergoing ECMO from 2006 to 2008 was performed. Linear regression correlations between anti-Xa, PTT, and ACT were determined by extrapolating PTT and ACT therapeutic ranges that corresponded with the ECMO heparin target range of 0.3 to 0.6 U/mL. Pearson correlation coefficients between heparin levels and PTT (-0.903 to 0.984), PTT less than 40 seconds after correction using PTT-heparinase (-0.903 to 1.000), and ACT (-0.951 to 0.891) in this patient population were widely variable. Inconsistency of PTT and ACT therapeutic ranges corresponding to heparin levels of 0.3 to 0.6 U/mL prompts a multifactorial approach to ECMO management because no single laboratory test can be used to determine appropriate anticoagulation management.
Medical subject headings
- Anticoagulants
- Extracorporeal Membrane Oxygenation
- Factor Xa
- Heparin
- Partial Thromboplastin Time