Cost/health effectiveness of home uterine activity monitoring in a Medicaid population.

Morrison, J C; Pittman, K P; Martin, R W; McLaughlin, B N · Obstet Gynecol · 1990

retrospective_cohort · Level III

Where this comes from

Abstract

It has been shown that an intensive system of preterm birth prevention using home uterine activity monitoring can decrease the number of early births. Such a system was employed in 130 public assistance (Medicaid) patients who were at high risk for preterm birth. A retrospective review of the pregnancy outcome in these subjects was conducted and their data exposed to a model for projected patient care cost. The incidence of preterm labor in the at-risk group was 46%, with an average prolongation of pregnancy of 4.9 weeks. The occurrence of preterm delivery for failed tocolysis or advanced cervical dilatation was less than 10%. Based on a cost-analysis model that considered newborn charges and monitoring expenses, nearly [corrected] $3 million (an average of $21,813 [corrected] per patient) was saved using this system.