Posterior C1-2 fusion using a polyaxial screw/rod system for os odontoideum with bilateral persistence of the first intersegmental artery.

Lee, Sun-Ho; Kim, Eun-Sang; Eoh, Whan · J Neurosurg Spine · 2011

case_report · Level V

Where this comes from

Abstract

The authors report the case of a patient with os odontoideum, myelopathy secondary to atlantoaxial instability, and bilaterally persistent first intersegmental artery at the craniovertebral junction. Instead of occipitocervical fusion, C1-2 posterior fusion was performed using a polyaxial screw/rod system. The information obtained from 3D CT angiography studies may highlight the potential risk of vertebral artery injury in advance and reduce the risk of an intraoperative vertebral artery injury. In addition, C-1 lateral mass screw placement may be a safe procedure for cases of atlantoaxial subluxation in which there are persistent C-1 intersegmental arteries.

Medical subject headings

Anatomy