The systemic inflammatory response following femoral canal reaming using the reamer-irrigator-aspirator (RIA) device.
other
Where this comes from
- Record sourced from PubMed, PMID 21144930.
- Also identified by DOI 10.1016/S0020-1383(10)70011-5.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We evaluated the peripheral release of inflammatory mediators after femoral fracture and subsequent intramedullary reaming using the RIA reamers. IL-6 was elevated after trauma, and reaming with RIA induced a measurable second hit response. However, despite a higher ISS, the levels of IL-6 in the RIA group were similar to the levels measured in a group of patients where reaming of the femoral canal was performed using conventional reamers. There was one death related to fat embolism syndrome in the conventional reamers group. However, the overall incidence of complications was low and similar between the 2 groups of studied patients. In polytrauma patients, large scale studies are desirable to evaluate further the immuno-inflammatory response using the RIA reamers prior to the instrumentation of the femoral canal.
Medical subject headings
- Femoral Fractures
- Fracture Fixation, Intramedullary
- Inflammation Mediators
- Interleukin-6
- Systemic Inflammatory Response Syndrome