Optimal configuration of the spiral linking technique for tendon repair. Biomechanical evaluation.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 21159722.
- Also identified by DOI 10.1177/1753193410390759.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A previous study described a new spiral linking technique for tendon repairs and demonstrated that it was strong enough to be used in clinical practice as an alternative to the Pulvertaft tendon weave repair. However the repairs were less stiff, needed slightly more tendon length for the same repair and were a little bulkier. In this study two variables have been changed with a view to improving the spiral technique. At first the number of spirals was reduced consecutively, keeping the same number of standard mattress sutures. Once the optimal number of spirals had been identified, repairs with different numbers of sutures were tested using an alternative cross-stitch technique. The spiral repair technique using two spirals linked with six sutures was at least as strong and stiff as a four-weave Pulvertaft technique and was also easier to do.
Medical subject headings
- Finger Injuries
- Suture Techniques
- Sutures
- Tendon Injuries