Potential bacterial contamination in fluorescein-anesthetic solutions.
Where this comes from
- Record sourced from PubMed, PMID 2116089.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the ability of fluorescein-anesthetic combination solutions and their applicators to regain sterility, we contaminated four commercially available fluorescein-anesthetic solutions and their dropper tips with inocula of either Pseudomonas species or Staphylococcus species. No organisms could be cultured from Fluress one minute after inoculation of the solution or five minutes after inoculation of the dropper tip. In contrast, organisms were cultured from the other fluorescein-anesthetic preparations for at least one hour after bacterial inoculation into the solution or onto the dropper tip. These differences in the ability of fluorescein-anesthetic solutions to regain sterility after bacterial contamination were statistically significant.
Medical subject headings
- Anesthetics
- Drug Contamination
- Fluoresceins
- Pseudomonas aeruginosa
- Staphylococcus aureus