Use of a chlorhexidine dressing to reduce microbial colonization of epidural catheters.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 2121070.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We performed a prospective randomized controlled trial to assess the efficacy of a chlorhexidine dressing in reducing the microbial flora at the insertion site of epidural catheters. These catheters were used for acute pain management and were dressed either by a standardized method or with a CHX/urethane sponge composite. Microbial colonization of the catheter developed in 9 of 31 controls (29.0%) and 1 of 26 (3.8%) catheters with the CHX dressing (P less than 0.05%). The CHX dressing caused no adverse effects. The data suggest that delivery of antiseptic to the catheter wound site reduces catheter colonization with a possible reduction in the risk of epidural catheter-related infection.
Medical subject headings
- Analgesia, Epidural
- Catheters, Indwelling
- Chlorhexidine
- Infection Control
- Postoperative Pain