Vessel boundary delineation on fundus images using graph-based approach.
Where this comes from
- Record sourced from PubMed, PMID 21216707.
- Also identified by DOI 10.1109/TMI.2010.2103566 and PMC identifier 3137950.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This paper proposes an algorithm to measure the width of retinal vessels in fundus photographs using graph-based algorithm to segment both vessel edges simultaneously. First, the simultaneous two-boundary segmentation problem is modeled as a two-slice, 3-D surface segmentation problem, which is further converted into the problem of computing a minimum closed set in a node-weighted graph. An initial segmentation is generated from a vessel probability image. We use the REVIEW database to evaluate diameter measurement performance. The algorithm is robust and estimates the vessel width with subpixel accuracy. The method is used to explore the relationship between the average vessel width and the distance from the optic disc in 600 subjects.
Medical subject headings
- Algorithms
- Diabetic Retinopathy
- Fluorescein Angiography
- Image Interpretation, Computer-Assisted
- Imaging, Three-Dimensional
- Pattern Recognition, Automated
- Retinal Vessels