The tension band principle and angular testing of extensor tendon repairs.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 21282214.
- Also identified by DOI 10.1177/1753193410396637.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Extensor tendons in the finger are flat and not amenable to repair by core and epitendinous sutures. Mattress sutures and Kessler repairs without epitendinous stitching are often used for extensor tendon divisions in the fingers. Except when in full extension, the finger presents a series of curved surfaces (at each joint) to the tendon. It was hypothesized that extensor tendons are subject to the 'tension band' principle and that they might be amenable to repair by dorsal-only epitendinous sutures. A Silfverskiöld dorsal-only repair was compared with mattress and Kessler repairs in vitro on a curvilinear testing apparatus. The epitendinous technique was found to be significantly more resistant to gapping and rupture, as well as more resistant to deformation (i.e. stiffer) than the conventional techniques.
Medical subject headings
- Finger Injuries
- Suture Techniques
- Tendon Injuries