Effect of surgical fit on integration of cancellous bone and implant cortical bone shear strength for a porous titanium.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 21316915.
- Also identified by DOI 10.1016/j.arth.2010.12.007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Porous scaffold dowels of Ti(6)Al(4)V were prepared and implanted into cancellous and cortical bone sites in adult sheep. Cancellous implants were examined under gap, line-to-line, and press-fit conditions, whereas line-to-line implantation was used in cortical sites. Cortical shear strength increased significantly with time and reached 26.1 ± 8.6 MPa at 12 weeks, accompanied by a concomitant increase in bone integration and remodeling. In cancellous sites, bone integration was well established at 4 and 12 weeks under conditions of press-fit and line-to-line match between implant and surgical defect. New bone growth was also found in the gap conditions, although to a lesser extent. These findings suggest that the porous Ti(6)Al(4)V could prove an effective scaffold material for uncemented fixation in cortical and cancellous sites.
Medical subject headings
- Femur
- Osseointegration
- Prostheses and Implants
- Shear Strength
- Tibia
- Titanium
Anatomy
- femur
- tibia