Intrauterine devices in early pregnancy: findings on ultrasound and clinical outcomes.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 21345405.
- Also identified by DOI 10.1016/j.ajog.2010.12.058.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of this study was to describe ultrasound findings, clinical symptoms, and outcomes of first-trimester pregnancies with intrauterine devices (IUDs). This was a retrospective review of 42 women with history of IUD placement and positive serum human chorionic gonadotropin in the first trimester. There were 31 intrauterine pregnancies (IUPs), 3 ectopic pregnancies, and 8 pregnancies of unknown location. Of 36 IUDs visualized, 15 were normally positioned and 21 malpositioned. Of 31 IUPs, 8 IUDs were within the endometrium, 17 were malpositioned, and 6 were not seen. Indications included bleeding (14 of 31), pain (12 of 31), and missing strings (5 of 31); 11 had no symptoms. Of 26 IUPs with known pregnancy outcomes, 20 were term deliveries and 6 had failed pregnancies of 20 weeks or less. More than half of IUDs identified in the first trimester were malpositioned. IUP was 3 times as likely with a malpositioned or missing IUD. Three quarters of the IUPs with known outcomes had term deliveries. Symptoms were not predictive of IUD malposition.
Medical subject headings
- Intrauterine Devices
- Pregnancy, Ectopic