A cell-phone-based brain-computer interface for communication in daily life.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 21436517.
- Also identified by DOI 10.1088/1741-2560/8/2/025018.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Moving a brain-computer interface (BCI) system from a laboratory demonstration to real-life applications still poses severe challenges to the BCI community. This study aims to integrate a mobile and wireless electroencephalogram (EEG) system and a signal-processing platform based on a cell phone into a truly wearable and wireless online BCI. Its practicality and implications in a routine BCI are demonstrated through the realization and testing of a steady-state visual evoked potential (SSVEP)-based BCI. This study implemented and tested online signal processing methods in both time and frequency domains for detecting SSVEPs. The results of this study showed that the performance of the proposed cell-phone-based platform was comparable, in terms of the information transfer rate, with other BCI systems using bulky commercial EEG systems and personal computers. To the best of our knowledge, this study is the first to demonstrate a truly portable, cost-effective and miniature cell-phone-based platform for online BCIs.
Medical subject headings
- Activities of Daily Living
- Cell Phone
- Communication Devices for People with Disabilities
- Electroencephalography
- Evoked Potentials
- Signal Processing, Computer-Assisted
- User-Computer Interface