A prospective evaluation of staging and target volume definition of lymph nodes by 18FDG PET/CT in patients with squamous cell carcinoma of thoracic esophagus.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 21470788.
- Also identified by DOI 10.1016/j.ijrobp.2010.10.065.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine an optimal standardized uptake value (SUV) threshold for detecting lymph node (LN) metastases in esophageal cancer using (18)F-Fluorodeoxyglucose positron emission tomography/computer tomography (18FDG PET/CT) and to define the resulting nodal target volume, using histopathology as a "gold standard." Sixteen patients with esophageal squamous cell carcinoma who underwent radical esophagectomy and three-field LN dissection after 18FDG PET/CT and CT scans were enrolled into this study. Locations of LN groups were recorded according to a uniform LN map. Diagnostic performance of different SUV thresholds was assessed by receiver operating characteristic analysis. The optimal cutoff SUV was determined by plotting the false-negative rate (FNR) and false-positive rate (FPR), the sum of both error rates (FNR+FPR), and accuracy against a hypothetical SUV threshold. For each patient, nodal gross tumor volumes (GTVNs) were generated with CT alone (GTVNCT), PET/CT (GTVNPET), and pathologic data (GTVNpath). GTVNCT or GTVNPET was compared with GTVNpath by means of a conformity index (CI), which is the intersection of the two GTVNs divided by the sum of them minus the intersection, e.g., CICT&path=GTVNCT&path/(GTVNCT+GTVNpath-GTVNCT&path). LN metastases occurred in 21 LN groups among the 144 specimens taken from the 16 patients. The area under the receiver operating characteristic curve was 0.9017±0.0410. The plot of error rates showed a minimum of FNR+FPR for an SUV of 2.36, at which the sensitivity, specificity, and accuracy were 76.19%, 95.93%, and 93.06%, respectively, whereas those of CT were 33.33%, 94.31%, and 85.42% (p values: 0.0117, 0.7539, and 0.0266). Mean GTVNCT, GTVNPET, and GTVNpath were 1.52±2.38, 2.82±4.51, and 2.68±4.16 cm3, respectively. Mean CICT&path and CIPET&path were 0.31 and 0.65 (p value=0.0352). Diagnostic superiority of PET/CT at an SUV threshold of 2.36 over CT has potential value in nodal target volume definition, but whether this can contribute to better treatment outcomes needs prospective analyses of recurrences in a larger cohort of patients.
Medical subject headings
- Carcinoma, Squamous Cell
- Esophageal Neoplasms
- Lymph Nodes