Surface electromyographic activity of five residual limb muscles recorded during isometric contraction in transfemoral amputees with osseointegrated prostheses.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 21474221.
- Also identified by DOI 10.1016/j.clinbiomech.2011.03.008.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Femoral osseointegrated implants represent a new development in amputee rehabilitation, eliminating socket pressure discomfort, improving hip range of movement and facilitating prosthetic limb attachment. A clinical aspect that has not previously been reported on is the function of muscles in the residuum with implications concerning energy expenditure, hip-hiking and viability of the electrogram as a myoprocessor. Typically, amputees fitted with osseointegrated fixation have shorter residuums and weaker attachment of cleaved muscles. Function of muscle can be assessed by surface electromyography through changes in amplitude and median frequency of the signal. Five male transfemoral amputees with osseointegrated fixations participated together with a control group comprised of ten adult males. Electrodes recorded surface electromyographic activity of five residual limb muscles or left lower limb muscles of control subjects. Isometric contractions were performed against resistance. The increase in mean rectified amplitude from resting to maximally contracting was calculated and median frequencies estimated. The amputees were unable to maintain a maximum voluntary contraction of constant amplitude. Amplitude increase was lowest for rectus femoris and adductor magnus. The median frequency of adductor magnus was significantly greater (P=0.02) for the amputees than intact subjects and there was a significant difference (P<0.01) between gluteus maximus and adductor magnus for amputee subjects. High electromyographic amplitude variability suggests that using residuum muscles singly as a myoprocessor might be challenging. Adductor magnus displayed a different sEMG profile compared to intact subjects indicating decreased function and neuromuscular changes. Further work into optimal muscle anchorage is required to ensure maximal mechanical performance.
Medical subject headings
- Amputation Stumps
- Amputees
- Electromyography
- Isometric Contraction
- Knee Prosthesis
- Muscle, Skeletal
- Osseointegration
Anatomy
- femur
- knee