Optimization of volar percutaneous screw fixation for scaphoid waist fractures using traction, positioning, imaging, and an angiocatheter guide.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 21527146.
- Also identified by DOI 10.1016/j.jhsa.2011.02.017.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Percutaneous screw fixation of nondisplaced or reducible scaphoid fractures has become more popular as techniques and implants have improved. Many authors have advocated for the dorsal approach, citing difficulties with adequate screw placement from the volar approach. We have developed a straightforward and reproducible technique for volar percutaneous scaphoid screw fixation that mitigates most of the drawbacks of the approach. The wrist is held in extension and ulnar deviation with traction through the thumb. A 14-gauge angiocatheter needle is then used to localize the starting point and as a cannula for the guide wire. Specific fluoroscopic views help to confirm optimal guide wire placement.
Medical subject headings
- Bone Screws
- Fracture Fixation, Internal
- Fractures, Bone
- Monitoring, Intraoperative
- Scaphoid Bone