Dynamic and volumetric variables of fluid responsiveness fail during immediate postresuscitation period.

Gruenewald, Matthias; Meybohm, Patrick; Koerner, Sebastian; Renner, Jochen; Maracke, Moritz; Schrezenmeir, Juergen; Steinfath, Markus; Bein, Berthold · Crit Care Med · 2011

basic_science · Level V

Where this comes from

Abstract

Fluid therapy after resuscitation from cardiac arrest is challenging since both hypovolemia and fluid overload may cause circulatory failure. Therefore, prediction of fluid responsiveness is a major issue in optimizing hemodynamic therapy. The aim of the present study was to evaluate the performance of stroke volume variation, pulse pressure variation, variation of Doppler-derived velocity time integral, and global end-diastolic volume index to predict fluid responsiveness in the postcardiac arrest period. Prospective animal study. University-affiliated research laboratory. Twenty anesthetized and ventilated Goettinger minipigs. Animals were equipped with a central venous catheter, a thermistor-tipped arterial catheter, and a transesophageal echo probe. Electrically induced cardiac arrest of 8 mins was followed by cardiopulmonary resuscitation. Hemodynamic measurements were performed before and after a two-step fluid bolus at baseline and both 1 and 4 hrs after return of spontaneous circulation. Fluid responsiveness was defined by an increase in stroke volume of at least 15%. Performance of variables was analyzed using receiver operator characteristics analysis. Variables reliably indicated fluid responsiveness at baseline. Fifteen animals were successfully resuscitated. Left ventricular ejection fraction was significantly reduced 1 hr after return of spontaneous circulation (52.6% ± 6.4%; p < .01) compared with baseline (69.9% ± 5.3%). One hour after return of spontaneous circulation, fluid responsiveness could not be predicted by any variable. In contrast, pulse pressure variation, variation of the velocity time integral, and global end-diastolic volume index, but not stroke volume variation, were able to predict fluid responsiveness 4 hrs after return of spontaneous circulation, since area under the curve was 0.85 (p < .01), 0.94 (p < .01), 0.77 (p = .02), and 0.68 (p = .12), respectively. Prediction of fluid responsiveness failed 1 hr after successful cardiopulmonary resuscitation from cardiac arrest. Four hours after return of spontaneous circulation, however, the variables pulse pressure variation, variation of the velocity time integral, and global end-diastolic volume index, but not stroke volume variation, enabled prediction of fluid responsiveness and may, therefore, be considered for subsequent hemodynamic optimization after successful cardiopulmonary resuscitation.

Medical subject headings