A new radioisotope tracing method of UHMWPE wear particle dispersion using 97Ru.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 21565725.
- Also identified by DOI 10.1016/j.jmbbm.2010.09.001.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A new method of radioisotope labelling, using the reaction 92Zr(12C,α3n)97Ru, has been demonstrated. The method places radioactive 97Ru tracer atoms into ultra-high molecular weight polyethylene (UHMWPE). The radioisotope 97Ru (half-life t1/2=2.9 days) was implanted in 5 mm×5 mm UHMWPE samples to a maximum depth of 5 μm. The radioisotope is identified via a characteristic gamma-ray emission from its daughter 97Tc at 216 keV. The new method is advantageous since the concentration profile of the 97Ru label is almost constant starting at the surface. In order to show the efficacy of the method for wear measurements on prostheses, the labeled UHMWPE samples were worn in a model system. The model system involved bi-directional sliding actuation on a steel block. Debris transport, via the two pathways linking the polymer with the articulating steel surface and with the lubricant, respectively, has been quantified. Surface roughness of the steel and the load on the steel were varied. Changing the surface roughness of the steel from (110±30) to (340±90) nm increased the amount of debris dispersed in the lubricant from (21±3)% to (67±3)%. Furthermore, changing the load from 1 to 5 kg also increased debris transport along this pathway.
Medical subject headings
- Isotope Labeling
- Polyethylene
- Ruthenium Radioisotopes