Enhancing the classification accuracy of steady-state visual evoked potential-based brain-computer interfaces using phase constrained canonical correlation analysis.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 21566275.
- Also identified by DOI 10.1088/1741-2560/8/3/036027.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In this study, a novel method of phase constrained canonical correlation analysis (p-CCA) is presented for classifying steady-state visual evoked potentials (SSVEPs) using multichannel electroencephalography (EEG) signals. p-CCA is employed to improve the performance of the SSVEP-based brain-computer interface (BCI) system using standard CCA. SSVEP response phases are estimated based on the physiologically meaningful apparent latency and are added as a reliable constraint into standard CCA. The results of EEG experiments involving 10 subjects demonstrate that p-CCA consistently outperforms standard CCA in classification accuracy. The improvement is up to 6.8% using 1-4 s data segments. The results indicate that the reliable measurement of phase information is of importance in SSVEP-based BCIs.
Medical subject headings
- Algorithms
- Evoked Potentials, Visual
- User-Computer Interface
- Visual Cortex
- Visual Perception